Features:

  • Module Based
  • Power Supplies Included
  • Flexibility to Perform Custom Experiments
  • Passive Components Included
  • Resistors, Capacitors and Inductors Loads Included
  • Control Circuits Included
  • P.T. and other Passive Components Included
  • Protection Circuits Included
  • Variable three-phase power supply
  • Line model
  • Three-phase transformer

Experiments Included:

Instrument Transformers Experiments

  • Determination of the transformation ratio of a current transformer for various primary currents and investigation on the influence of the load on the transformation ratio.
  • Explanation of the terms: ratio error (current error), accuracy class and rated accuracy limit factor.
  • Test on the performance of the current transformer at over-current.
  • Assembly of the common current transformer circuit for measurement on three-phase network.
  • Measurements of the zero-phase sequence current of a three-phase system.
  • Measurements on a summation current transformer.
  • Demonstration of the principle of differential protection.
  • Determination of the transformation ratio of a voltage transformer for various primary voltages and investigation on the influence of the load on the transformation ratio.
  • Explanation of the terms: ratio error (voltage error) and accuracy class.
  • Assembly of the common voltage transformer circuit for measurements in three-phase network.
  • Measurement of the residual voltage in a three-phase system with a fault to ground.
  • Assembly of a voltage transformer circuit in open delta connection.
  • Measurement of the three conductor voltages on symmetrical and asymmetrical loads.

Protective Relays Experiments

  • Connection of an under/over voltage relay in a three-phase network and investigation on its behavior with respect to under and overvoltage.
  • Connection of an inverse time over-current relay in a three-phase network and investigation on its behavior with respect to different settings.
  • Measurement of the operating time of an inverse time over-current relay.
  • Investigation on an earth-fault relay.
  • Demonstration of an earth-fault alarm in a three-phase network.
  • Reaction to so-called transient earth faults.
  • Investigation on a directional earth-fault relay behaviour for effective currents and on the direction of operation.
  • Investigation on a combined over-current and earth-fault relay behavior connected in a solid earthed three-phase network.

Protection of HV Line Experiments

  • Connection of an under/over voltage relay in a three-phase network and investigation on its behavior with respect to under and overvoltage.
  • Determination of the resetting ratio of an under/over voltage relay.
  • Measurement of the operating time of an under/over voltage relay.
  • Connection of a definite time over-current relay in a three-phase network and investigation on its behavior with respect to different settings.
  • Determination of the resetting ratio of a definite time over current relay.
  • Measurement of the operating time of a definite time over-current relay.
  • Demonstration of an earth-fault alarm in a three-phase network.
  • Reaction to so-called transient earth faults
  • Connection of an inverse time over-current relay in a three-phase network and investigation on its behavior with respect to different settings.
  • Measurement of the operating time of an inverse time over-current relay.
  • Investigation on an earth-fault relay.
  • Check of the operate time set.

Protection of HV Line Experiments

  • Demonstration of how an under/over voltage time relay monitors the protection of a load against under-and over-voltage.
  • Demonstration of the protection of a transmission line against the Reverse Power fault

In an Electrical Power System currents and voltages must be monitored constantly to ensure that the values remain within the required limits. This will also switch off the faulty sections from the main supply network.

It is important to identify the fault and isolate the faulty section automatically from the network because this will collapse the entire electrical power system. These protection systems need to be fast and reliable in events of fault in order to avoid any large-scale damage. It is important that the protection system identifies and isolates the faulty section without affecting the remaining power system.

A number of protective relays are analyzed: under/over voltage time relays, definite time over-current relays, inverse time over-current relays, combined over-current and earth-fault relays, directional relays, and earth-fault relays.

List of Electrical Power Trainer

Description Module Qty
Variable Three-Phase Power Supply

  • Power supply provides variable 3-Phase Voltage
  • Key Operated Emergency Switch
  • Protection: 10 A, Direct On Line (DOL) Starter
  • Push-Button: Start, Stop, and Emergency
  • Motor Protection Breaker: 10 A
  • Digital 3-phase analyzer
  • Output Adjusted by Rotary Knob
  • Output: 3 x 0-380 V @ 8 A
  • Supply voltage: Three-Phase from Mains
IT-6000 1
Line Model

  • Simulated Length: 360km
  • Simulated Voltage: 380kV
  • Simulated Current: 1000A
  • Scale factor: 1:1000
  • Mutual capacitance: 1mF
  • Earth capacitance: 2mF
  • Line resistance: 13Ω
  • Line inductance: 290 mH
  • Earth resistance: 11Ω
  • Earth inductance: 250 mH
IT-6002 1
Three-Phase Transformer

  • Scale Factor: 1:1000
  • Primary Input: 3 x 380 V
  • Connection Type: Star or Delta
  • Secondary Output: 3 x 220 V windings with taps at +5%, -5%, -10%, -15%
  • Star connection for 3 x 380 V various star connections possible
  • Power: 800 VA
  • Tertiary Output: 3 x 220 V windings
  • Delta connection for stabilizing the third harmonic voltage components
IT-6003 1
Resistive Load

  • Max Load in 3-Phase: 1200 W
  • Rated voltage: 380/220V
  • Connection Type: Y/
  • Rated voltage in single-phase: 220 V
IT-6004 1
Inductive Load

  • Max Reactive Power: 890 Var
  • Rated voltage: 380/220 V
  • Connection Type: Y/
  • Rated voltage in single-phase: 220 V
IT-6005 1
Experiment Transformer (0-250 V @ 5 A)

Outputs:

  • Single-Phase: 0-250 V @ 3 A
  • Protection: 10A Breaker, Fuse 2.5A and Fuse 5A
  • Low voltage Single Phase:
  • 0-42 V @ 3 A
  • 0-24 V @ 6A
  • 0-12 V @ 12 A
  • DC Voltage: 50 A Rectifier for all ranges
IT-6016 1
Three-Phase Power Supply

  • Digital 3-phase analyzer
  • Input: 3-Phase 380V
  • Output Protection: 30 A current-operated earth leakage circuit breaker
  • Four-pole motor protection switch: 6.3-12 A.
  • Three-phase indicator lamps
  • Output through 5 safety terminals: L1, L2, L3, N and PE
IT-6017 1
Power Circuit Breaker with Integrated PLC

  • PLC integrated inside
  • Contact Load: 400 VAC @ 3 A
  • Supply Voltage: Single-Phase from the mains
IT-6019 1
CT Load

  • Load for the single-phase current transformer consisting of two separated ohmic resistors
  • Fixed resistor: 0.5 Ω, load 7 A
  • Variable resistor: 0 … 60 Ω, load 1 A
  • Range: 0 … 100%
  • Fuse Protection: 1A
IT-6023 1
VT Load

  • Load for the single-phase voltage transformer consisting of two separated ohmic resistors
  • Fixed resistor: 220 Ω
  • Load: 0.5 A (0.5 A fuse)
  • Variable resistor: 330-1930 Ω
  • Load: 0.25 A fused
IT-6024 1
Under/Over Voltage Time Relay

  • Function: Under/Over Voltage, Phase Sequence(L1,L2,L3) and Phase Failure Detector
  • Supply: 380V
  • Delay: 0.5-30sec
  • Output Relay: 230VAC @ 5A
  • Frequency: 50/60Hz
IT-6025 1
Combined Over Current & Earth Fault Relay

  • Three Phase inputs from the mains
  • Current Range: 0~5 A
  • Output Relay: 250VAC @ 5A
  • Adjustable operation time
  • Over current protection
  • Inverse time over current protection
  • Earth fault Protection
IT-6026 1
Definite Time Over-Current Relay

  • Single Phase inputs from the mains
  • Current Range: 0~6 A
  • Output Relay: 250VAC @ 5A
  • Adjustable operation time
  • Adjustable delay time
  • Trip Time: 0-10 sec
IT-6027 1
L/C Loads

  • Suitable for insertion of fault types to trigger the single-phase directional relay.
  • Inductance: 0.1, 0.2, 0.3, 0.4 H
  • Rated voltage: 220 V, 50 Hz
  • Rated current: 0.5 A
  • Capacitance: 2, 4, 8, 16 mF
  • Rated voltage: 450 V AC
IT-6030 1
Moving Coil Ammeter (1000mA)

  • Range:  0-1000 mA AC
IT-6034 4
Moving Coil Ammeter (3A)

  • Range: 0~2.5 A  AC
IT-6035 1
Moving Iron Ammeter (5A)

  • Range:  0-5A AC
IT-6036 2
Moving Iron Voltmeter (500V)

  • Range: 0-500V AC
IT-6038 4
Single-Phase Current Transformer

  • Primary Current: 5/1 A
  • Secondary Current: 1 A
  • Frequency: 50 Hz – 60 Hz
IT-6043 1
Three-Phase Current Transformer

  • Primary Current: 5/1 A
  • Secondary Current: 1 A
  • Frequency: 50 Hz – 60 Hz
IT-6044 1
Single-Phase Voltage Transformer

  • Primary Voltage: 220V
  • Secondary Voltage 33V @ 15VA
  • Secondary Voltage 65V @ 5 VA
  • Frequency: 50 – 60 Hz
IT-6045 1
Three-Phase Voltage Transformer

  • Primary Voltage: 380 V
  • Secondary Voltage: 33 V @ 15VA
  • Secondary Voltage: 65 V @ 5 VA
  • Frequency: 50 Hz – 60 Hz
IT-6046 1
Summation Current Transformer

  • Primary Rated Current: 5 x 2.5 A
  • Transformation Ratio: 2.5/1
  • Secondary Rated Current: 1 A
  • Rated power: 5 VA
IT-6047 1
Reverse Power Relay

  • Reverse Power Relay
  • Nominal Current: 5A
  • Nominal Voltage: 230/380 VAC
  • Frequency: 50/60Hz
  • Calibrated Scale: 2 to 20% reverse current (adjustable)
  • Time Delay: 0.2 to 20 seconds (adjustable)
  • Repeatability: Better than 0.5% of nomina
IT-6076 1
Base Frame

  • 2-Level Frame
IT-2L 1
Leads (Accessory)

  • 1 set: 120 Pcs
IT-ACC 1set

 

Expansion Module (optional):

IT-6059

  • Differential Transformer Relay : 1pc

IT-6044

  • Three Phase Current Transformer : 2pcs

IT-6058

  • Feeder Manager Relay : 1pc

IT-6074

  • Over/Under Frequency Relay : 1pc

IT-6075

  • Synchronous Check Relay : 1pc

Experiments with Expansion Module:

  • Definite time over current protection
  • Inverse time over current protection
  • Earth fault
  • Transformer differential protection
  • Directional Earth Fault
  • Distance Earth Fault
  • Over/Under Frequency Protection
  • Synchronization Check